d n = 0.005 i n c h × 92 ( 36 − n ) / 39 = 0.127 m m × 92 ( 36 − n ) / 39 {\displaystyle d_{n}=0.005~\mathrm {inch} \times 92 Increasing gauge numbers denote logarithmically decreasing wire diameters, which is similar to many other non-metric gauging systems such as British Standard Wire Gauge (SWG). However, AWG is dissimilar to IEC 60228, the metric wire-size standard used in most parts of the world, based directly on the wire cross-section area (in square millimetres, mm²). The AWG originated in the number of drawing operations used to produce a given gauge of wire. Very fine wire (for example, 30gauge) required more passes through the drawing dies than 0gauge wire did. Manufacturers of wire formerly had proprietary wire gauge systems; the development of standardized wire gauges rationalized selection of wire for a particular purpose. The wire size chart below shows allowable ampacities of insulated conductors rated up to and including Results may change with real wires: different resistivity of material and number of strands in wire The n gauge wire diameter d n in inches (in) is equal to 0.005in times 92 raised to the power of 36 minus gauge number n, divided by 39:

The most common method of referring to conductor sizes uses the cross-sectional area, expressed in mm². The following AWG metric conversion table converts AWG to mm and inches, and also lists the cross sectional area (mm2). AWG Metric Conversion Chart (AWG to mm) Each component or appliance connected to a circuit will have a current draw associated with its operation and it is important that the cable supplying power to these is capable of carrying the normally expected current, plus a margin of safety. If it is not capable then it is likely to result in the cable becoming hot and potentially catching fire. Although fuses are used in the circuit to protect the cable, the cable itself should be of an adequate rating to prevent this over-heating occurring under normal circumstances.

Anyway, enough maths - to make it easy we've developed this handy calculator which will show you the approximate voltage drop based on cable size, supply voltage, current draw and cable length.

In Europe, metric sizes are used for stranded cableand are expressed as the total cross sectional area of the conductors together with the number of strands and their diameter. For example, a cable specified as 2.0mm² 28/0.30 indicates that it has a total conductor cross sectional area of 2.0mm² and is made up of 28 individual strands, each of 0.3mm diameter. All elements of an electrical circuit have resistance, including electrical cable, which means that there will be energy loss in the form of voltage drop experienced along the length of the cable. Just as a bulb converts electrical energy into heat and light due to its resistance, and so induces a voltage drop, a copper conductor has resistance and will convert some of the energy it conducts, causing a voltage drop in the same way. The difference is that voltage drop across a bulb (or other load) is useful as that's what makes it work, but voltage drop along cable and other passive parts of a circuit is not desirable as it's not a useful conversion of energy.Change the temperature, if necessary. The value should be the maximum operating temperature that is expected for the wire.

This problem is overcome by manufacturing the core from many small diameter strands of copper wire to make up the desired cross-sectional area, rather than using a single wire. This type of cable is (unsurprisingly) known as 'stranded' cable and provides much more flexibility, which means improved resistance to work hardening making it better suited to use in vehicles. The difference in cross sections is shown in the diagram below: Input what percentage voltage drop is allowable. The smaller, the better, but the limit is 5% to keep devices working properly. There is a general rule of thumb that says if you're unsure whether the cable is large enough for the job, go up a size. This is a bit crude and not very scientific but it's not a bad rule to apply as increasing cable size can't do any harm. This is the resistance of the conductor expressed in Ohms per metre ( W/m) and is important when determining voltage drop (see below)In the US, the most commonly used wire gauge system is AWG, or American Wire Gauge. The higher the gauge number, the smaller the wire. AWG is also commonly used to specify body piercing jewelry sizes (especially smaller sizes), even when the material is not metallic. [2] Formulae [ edit ] It has sufficient current rating for the expected load in the circuit, including a margin of safety. The largest diameter AWG size is 0000 (4/0) which is pronounced ‘four aught’, representing a diameter of .46″. The smallest diameter is 32 AWG, representing .00795″. By definition, No. 36 AWG is 0.005 inches in diameter, and No.0000 is 0.46inches in diameter. The ratio of these diameters is 1:92, and there are 40 gauge sizes from No.36 to No.0000, or 39 steps. Because each successive gauge number increases cross sectional area by a constant multiple, diameters vary geometrically. Any two successive gauges (e.g., A and B ) have diameters whose ratio (dia. B ÷ dia. A) is 92 39 {\displaystyle {\sqrt[{39}]{92}}} (approximately 1.12293), while for gauges two steps apart (e.g., A, B, and C), the ratio of the C to A is about 1.12293 2 ≈ 1.26098.

While the AWG is essentially identical to the Brown & Sharpe (B&S) sheet metal gauge, the B&S gauge was designed for use with sheet metals as its name suggests. These are functionally interchangeable but the use of B&S in relation to wire gauges, rather than sheet metal gauges, is technically improper. This shows that although 0.5mm² cable is OK for the expected current draw of the light, it's not OK for the cable run length as the drop is greater than 3%. In North America the AWG standard is most commonly used for stranded cable and expresses the Gauge together with the number of strands and their Gauge. For example, a cable specified as 16 AWG 7/24 has a size of 16AWG and is made up of 7 individual strands, each of 24 AWG. Thirdly, the harder grade of PVC is more reistant to abrasion and cutting than standard PVC, offering more protection and greater reliability. In most situations the detrimental effects can be minimised by using shrink sleeving, sealed connectors, adhesive lined terminals, protective gels etc. to keep moisture out, but in some applications where the environment is particularly aggressive, for example marine use, it might be preferable to use cable with tinned conductors. This is simply where the standard plain copper conductor has has a layer of tin applied before being sheathed in the insulation.Tin doesn't react in the presence of moisture, yet retains good conductivity, and so improves long-term performance of the cable. The downsides are that it is slightly more expensive and there is a more limited range of sizes and colours available compared with plain copper. Earth braid straps that have no insulating layer are typically tinned for protection as a matter of course.For more information regarding wiring and cables, see our comprehensive guide here. AWG Gauge Table AWG gauge